Third-party laboratory report

Disinfectant — available chlorine stability and acute oral toxicity

Three determinations on the 消毒除味液(次氯酸)sample: pH 6.96 at 25 °C; available chlorine 130 mg/L before storage against 111 mg/L after 14 days at 54 °C — a 14.6% fall, inside the ≤15% that GB/T 38499-2020 sets for a one-year shelf life; and an acute oral toxicity test on 20 mice.

Report number
XJ2025001233
Issued by
Guangzhou Institute of Microbiology Group Co., Ltd.
Test
Available chlorine stability
Product line
Disinfection
Covers SKUs
P003
Published by
Guangdong Shenhe Zhongke Biotechnology Co., Ltd. — Heyuan, Guangdong, China
Issued by (third party)
Guangzhou Institute of Microbiology Group Co., Ltd.
How to verify it
Issued by the Guangzhou Institute of Microbiology Group Co., Ltd., a third-party laboratory. The number carries the group's own XJ entrustment prefix, and the report is a five-page document with the sample name and the entrusting party printed on it. No public lookup page was found for XJ numbers, so the buyer writes to the group quoting the number and the sample name.
Download the PDF ← All certifications and reports

What this report covers

This report documents the product made here. A private-label version of the same formula needs its own testing for the claims you intend to make — tell us the market and the claim, and we will confirm the sample, the method and the cost in writing before anything is ordered.

Request a quote

This report is issued by Guangzhou Institute of Microbiology Group Co., Ltd., a third-party laboratory — not by the supplier. The supplier is Guangdong Shenhe Zhongke Biotechnology Co., Ltd. Issued by the Guangzhou Institute of Microbiology Group Co., Ltd., a third-party laboratory. The number carries the group's own XJ entrustment prefix, and the report is a five-page document with the sample name and the entrusting party printed on it. No public lookup page was found for XJ numbers, so the buyer writes to the group quoting the number and the sample name. The report documents the product made here; a private-label version of the same formula needs its own testing for the claims the buyer intends to make. Report number XJ2025001233 is the reference to quote back.